Issue: 

When getting the post-processor file(*.znc, *.mdf), how to use it to output the NC codes?

Solution:

  1. About the *.znc file, please save it in the ZWPostConfigs folder in the installation directory. (e.g., C:\Program Files\ZWSOFT\ZW3D 2026\ZWPostConfigs)
  2. Sometimes, we also need to use the *.mdf file. Please save it in the output_def folder of the corresponding language version. (e.g., C:\Program Files\ZWSOFT\ZW3D 2026\languages\en_US\output_def)
    (If the *.mdf file is not provided, skip this step.) 
  3. Select the corresponding Post Configuration and Definition File in the Machine Manager. Then, the NC codes can be output with the post-processor.


CN Solution
JP Solution

★How to use the post-processor file in ZW3Dhttps://confluence.zwcad.com/pages/viewpage.action?pageId=342229255