Issue:
After the network license server is deployed, a client may show the message:“No license available on the server. Please check the server and port settings, then query again.” How can this be resolved?
Solution:
- The issue is usually caused by port conflicts. Click the Config button in the server's Network License Manager to check if the port is occupied.
- If the port is occupied, change it to any port between 27000 and 27009. Save the settings, then restart the ZWSOFT License Manager.
- On the client, enter the new port number (such as 27001) and retrieve the license again. The client will be activated successfully.
| CN Solution | ☆中望CAD网络版客户端授权时,提示“服务器上许可证为空” |
|---|---|
| JP Solution |
☆“No license is available on the server” When activate floating license of ZWCAD:https://confluence.zwcad.com/pages/viewpage.action?pageId=321162358