Issue:
When using the ZWMSINGLEHOLE command in ZWCAD MFG, the selected hole type is remembered within the current drawing but reverts to the default value for new drawings. How to change the default type of the single hole function?
Solution:
- Locate the file named Option.xml in the ZWCAD MFG resource folder at C:\Users\Public\Documents\ZWSoft\zwcadm\2024\en-US\styles\ISO and open the file with Notepad.
(Note: The actual path depends on the drawing frame standard used by the user) - Find the text <FieldMap DestName="SHOLE_DATA_TYPE" SrcName="1"/>, modify the value of SrcName, and then save the file. The settings modification of the single hole default type will take effect after restarting ZWCAD MFG.
(Note: The values 1, 2, 3, and 6 represent a round hole, a double round hole, an internal threaded hole, and an external threaded hole, respectively.)
| CN Solution | ★中望CAD机械版如何设置单孔的默认类型 |
|---|
★How to set the default type of the single hole in ZWCAD MFG:https://confluence.zwcad.com/pages/viewpage.action?pageId=177480967