Issue:

When using numeric shortcut keys such as "1", "2", etc. in ZWCAD MFG, there is no response from the software, what might be the reason?

Causes:

The definition of the numeric shortcut keys in ZWCAD MFG is stored in the file supedit.lsp from the MFG installation directory path: xxx\zwcad MFG\Zwcadm\supedit.lsp. Firstly confirm whether this file is normal, and then load it in the ZWCAD MFG.

Solution:

  1. Open the file supedit.lsp located in the installation directory path: xxx\zwcad MFG\Zwcadm using Notepad, and check if there is any content and whether there is garbled text inside
  2. If the supedit.lsp file is missing or the content is problematic, please copy the file from another computer or click the link to download it: supedit.lsp
  3. Open ZWCAD MFG, click the menu Tools → Load Application (APPLOAD command) and load the file, add it to the startup suite and click the OK



★Why numeric shortcuts cannot be used in ZWCAD MFGhttps://confluence.zwcad.com/pages/viewpage.action?pageId=174163128