Issue:

After selecting Replace Z value with current elevation through the Options dialog box, closing ZWCAD and reopening the file, finding that the setting hasn't been saved and remains unselected.
How to keep Replace Z value with current elevation selected by default?

Causes:

The default value for OSNAPZ is 0 (zero), and this setting is not a saved variable in ZWCAD drawings. So the option to Replace the Z value with the current elevation is deselected in the Options dialog box when reopening the drawings.

Solution:

Add a statement to the ZWCAD20XXdoc.lsp file to modify the default value of the OSNAPZ variable when the software starts.

  1. Right-click the software icon to open the file location.
  2. Go to the directory ZWSOFT\ZWCAD 2026\Support\en-US,  find the ZWCAD20XXdoc.lsp file, and open it with Notepad.

  3. Add the statement (setvar "OSNAPZ" 1) at the end of the text, and save the file.

       

CN Solution


★Why dose ZWCAD fail to save the selection of "Replace Z value with current elevation" when reopen the filehttps://confluence.zwcad.com/pages/viewpage.action?pageId=331744830